Makrolab LTD
  • UKR
  • RUS
+38 (067) 537-32-57
info@macrolab.com.ua
  • UKR
  • ENG
  • RUS
Меню
  • Laboratory equipment
    • XRF fluorescence spectrometers and X-ray diffractometers. Particle size analyzers
      • XRF analyzers
      • Infrared spectrometers
      • X-ray diffractometers
      • Particle size analyzers
      • X-ray tubes for diffractometers and spectrometers
      • Accessories for Mastersizer 3000+ Ultra, Mastersizer 3000+ Pro and Mastersizer 3000+ Lab laser diffraction analyzers
      Retsch laboratory mills
      • Ball mills
      • Disc Mills
      • Mixer mills
      • Mortar grinders
      • Knife mills
      • Cutting mills
      • Drum mills
      • Jaw Crushers
      • ROTOR MILLS
      • Sieving machines
      • Test sieves
      • Sample dividers
      • Dryers
      • Pellet presses
      • Crushability tester
      • Vibrating feeder
      • Ultrasonic bath
      ELEMENTAL ANALYZERS
      • Analyzers C-N-H-S
      • Analyzers of carbon, hydrogen, sulfur in organic and inorganic materials
      • ONH analyzers for oxygen, nitrogen, hydrogen in inorganic materials ELTRA
      • Thermogravimetric analyzers
      • The Software for Elemental Analyzers
      Hardness testers, metallography and materials science QATM
      • Micro hardness testers
      • Rocwell hardness tester
      • Latest technology in universal hardness testing
      • Customized hardness testing solutions
      • Software
      • Cut-off machines
      • Floor-standing Cut-off Machines
      • Clamping tools
      • Consumables
      • Hot mounting presses
      • Pre-Grinder
      • Manual grinder & polisher
      • Automatic grinding & polishing
      • Fully automated systems
      • Electrolytic polisher and etcher
      High temperature muffle furnaces and drying ovens Carbolite Gero
      • Laboratory ovens to 700°C
      • Industrial drying ovens up to 750 °C
      • Clean room ovens
      • Atmosphere Controlled Ovens
      • Laboratory ovens up to 1800°C
      • Industrial muffle furnaces up to 1800°C
      • Muffle furnaces for combustion (ashing) up to 1200°C
      • Annealing furnaces & ovens
      • Universal tube furnaces up to 1800 °C
      • Split tube furnaces up to 1800 °C
      • Rotary tube furnaces
      • Gradient Tube Furnaces
      • Accessories and configurations for tube furnaces
      • Vacuum Chamber Furnaces
      • Vacuum hood furnaces
      • Vacuum bottom loader furnaces
      • Vacuum Laboratory Furnaces
      • Vacuum Tube Furnaces
      • Asphalt Binder Analyzer
      • Tritium Furnaces
      • Furnaces and ovens for testing coal and coke
      • Custom designed furnaces & ovens
      • Controllers
      Spectrometers ARUN Technology
      Microwave systems by CEM company
      • Microwave Digestion
      • Extraction
      • Quality control in production
      • Chemical synthesis
      • Peptide Synthesis
      • Microwave Drying
      • Hydrolysis
      Professional weather stations by Davis Instruments
      • Weather stations Vantage Vue
      • Professional weather stations Vantage Pro2
      • Replacement Parts
      Laboratory argon purifiers Sircal Instruments
      Scanning Electron Microscopes SEM and FIB-SEM
      Heating microscopes Hesse Instruments
  • Industrial equipment
    • High pressure homogenizers Microfluidizers
      • High-pressure Benchtop Homogenizers
      • Pilot Scale Homogenizers
      • Production Scale Homogenizers
  • News
  • About the company
  • Our partners
  • Contacts
    • Main
    • Catalog
    • Laboratory equipment
    • High temperature muffle furnaces and drying ovens Carbolite Gero
    • Custom designed furnaces & ovens
    • Ovens and tare cabinets with sample weigher
Ovens and tare cabinets with sample weigher0
Ovens and tare cabinets with sample weigher0

Ovens and tare cabinets with sample weigher

Артикул: SAMPLE WEIGHING

MASS LOSS DURING HEAT TREATMENT IN AIR

For organic matter the standard ashing furnace AAF 11/17 with balance up to 1100°C can be used for loss on ignition (LOI) applications in air. Weight change of the sample is monitored during the heating process and this is required, for example, in the determination of organic matter content in materials such as sediment, sludge, soil and waste.
For inorganic matter the standard CWF-BAL furnace, up to 1100°C, with integral balance can be used for thermogravimetric analysis (TGA) and loss on ignition (LOI) applications in air, where weight change of the sample must be monitored during the heating process. This is required, for example, in the determination of inorganic matter content in materials such as cement, lime, calcined bauxite and refractories.

MASS LOSS DURING HEAT TREATMENT UNDER INERT GAS ATMOSPHERE

Under inert gas custom made ovens and furnaces can be fitted with a balance for continuous sample weighing. A heated gas outlet with either an active after burner or a condensation trap is recommended for certain amounts of organic matter.

CARBOLITE GERO CUSTOM FURNACES & OVENS EXAMPLES

 
Custom made retort furnace up to 900°C for 250kg load with balance (accuracy 5g) for mass loss under inert gas atmosphere
AAF-BAL 11/17 with balance for determination of organic matter content
Bespoke HTMA 6/96 up to 600°C under inert atmosphere with custom designed continuous sample weighing
Makrolab LTD

SAMPLE PREPARATION & ELEMENTAL ANALYSIS

Directory

  • Laboratory equipment
  • Industrial equipment

Information

  • About the company
  • News
  • Our partners
  • Contacts

Contact us

  • 03127, Ukraine, Kyiv, 122 Holosiivskyi Avenue, building 1, office 91,
  • +38 (067) 537-32-57
  • +38 (050) 386-57-70
  • +38 (044) 258-34-01
  • +38 (044) 258-34-02
  • info@macrolab.com.ua
© Makrolab LTD - 2025
Design with by Web-Studio Gold Fish.

This site uses cookies and similar technologies to ensure maximum user experience. By using this site, you confirm your consent to the use of cookies in accordance with this notice regarding this type of files.

Contact manager

Ovens and tare cabinets with sample weigher (SAMPLE WEIGHING)

Message