ORACLE™ is the first ever rapid fat analyzer that requires absolutely no method development for fat only analysis. At the touch of a button, ORACLE can analyze fat in any food sample with reference chemistry accuracy, without any prior knowledge of the sample matrix or composition. Simply press the run arrow and ORACLE delivers an exceptionally accurate and precise fat result in 30 seconds. Alternatively, ORACLE can be paired with the SMART 6 for combined rapid fat and moisture/solids analysis in less than 5 minutes.
Unique Chemistry
Newly developed NMR technology that completely isolates protons in fat from all other proton sources in food matrixes, such as carbohydrates and proteins.
Features
- Rapid- 30 second analysis
- Analyze any sample from 0.05 – 100.00 % fat
- Direct isolation and measurement of hydrogen protons on fat molecules
- Precise- better repeatability than wet chemical extraction techniques
Fat Analysis
Absolutely NO method development
ORACLE is the first ever rapid fat analyzer that requires absolutely no method development. ORACLE provides reference chemistry accuracy for any food sample without any prior knowledge of the sample matrix and composition. Simply press the run arrow and in 30 seconds the ORACLE delivers a fat result. It’s really that simple.
ORACLE can also be paired with an automated robot for unattended analysis of 100 samples per run.
Moisture/Solids and Fat
Rapid analysis in < 5 minutes
Pair the SMART 6 Moisture & Solids Analyzer with the ORACLE for rapid moisture/solids and fat in one system. The SMART 6 utilizes dual-frequency energy to rapidly analyze moisture/solids in any product, wet or dry, in approximately 3 minutes. The system comes pre-programmed with a library of optimized drying methods for pairing with the ORACLE.
Validation:
- AOAC 2008.06 - Moisture and Fat in Meats
- AOAC PVM 1:2004 - Moisture/Solids and Fat in Dairy Products
ORACLE is unique
Major breakthrough in NMR technology
- Newly developed technique achieved in 2016
- Technology completely isolates the detection of the proton signal in fat molecules from all other compositional proton sources (i.e. protein, carbohydrate, ash) making a universal fat analyzer possible
- Alternative rapid techniques are unable to fully isolate fat from other components, which is why extensive calibration development is often required
Accurate Analysis
Get an accurate analysis of any food sample in only 30 seconds
ORACLE was verified with over 30 Certified Reference Materials (CRM’s) sourced from Europe and USA. These trusted samples undergo extensive reference testing in numerous certified laboratories and provide a benchmark for any food testing methodology. The blue data in the graph shows the linearity between the CRM reference results and the ORACLE rapid fat results. Since CRM’s are limited in their available matrices, CEM also outsourced hundreds of samples to third party testing laboratories for wet chemical reference chemistry analysis. The red data in the chart shows the comparison between the outside lab reference results and ORACLE.
Samples
Dairy | Meat | Processed Foods
|
- Butter
- Cheese
- Chocolate Milk
- Cream (Heavy)
- Eggs
- Formula (Infant)
- Ice Cream
- Milk
- Whey
- Yogurt
| - Bacon
- Cod
- Chicken
- Duck
- Ground Beef
- Ham
- Hot Dog
- Lamb
- Pork
- Salmon
- Sausage
- Turkey
- Venison
| - Coffee Creamer
- Chips
- Cookies
- Crackers
- Dog Food
- Dough
- Dressings
- Gravy Granules
- Guacamole
- Mayonnaise
- Mixed Foods
- Noodles
- Nutritional
- Drinks
|
Get consistent results, anywhere in the world
Perfect for corporate integration
All ORACLES are manufactured and designed to produce the same results worldwide, making the system an ideal solution for corporations seeking to standardize rapid instrumentation. Alternative rapid fat analyzers are susceptible to differences in optics and system components, which prevents them from transferring methods between various locations. That means that each system requires unique method development, which ultimately translates to extensive time and capital. Plus, there’s no guarantee that the results will match.
Since ORACLE does not require method development and all the systems are the same, users can rest assured that all sites will get the same accurate, consistent results. What does that mean? A pet food distributor in Texas will get the same accurate ORACLE fat result as its parent manufacturer in California and the primary fish and meat suppliers in Australia and Japan.
Workflow
ORACLE will fit right into your workflow in NMR technology
Easy to Use
Simply press the run arrow, enter the sample ID and mass, and get a fat result in less than 30 seconds.
No Chemist Required
Anyone can walk up to the system and understand operation in no time, which makes training new employees simple.
Versatile
ORACLE can be used in a laboratory or at-line on a production floor.
- Integrates seamlessly with LIMS (Laboratory Information Management System)
- Ergonomic barcode scanner and stand are included with each system
- Imports sample barcodes directly into sample ID for data storage and recall
- Scans numerous barcode types including UPC, EAN, Code 39, ITF, QR Code, Datamatrix code, and many others...